Re: 59 apache coil question

Quote:
Originally Posted by dwcsr View Post
You have something wrong with the regulator. A generator will put out as much a 28 volts at 20 amps so what your seeing can happen. The regulator is defective , miss wired , not polarized or a wire shorted shorted. 25 volts will cook your coils quickly. It needs 9 volts max
Ok, I learn something here too. Thank you Dave I did not think that voltage was possible from a 12V system.