Re: HP Tuners Tutorials - Volumetric Efficiency VE Table Calibration
Volumetric Efficiency VE Table Calibration
and here are the detailed properties of that graph
Label: call it what ever you want "VE Tune" or "LTFTSTFT VE" what ever fits in that little box
Parameter: LTFT + STFT [Math] this is a special computation provided to us by HP Tuners
Cell Hits Required: the more the better I think I usually set this to 20
High Value: 20 make it show lean in Red
Low Value: -20 make it show rich condition in Green
Column Axis
Parameter: and here's our X axis aka Engine Speed [Sensor] aka RPM
Note: to make RPMs look like RPMs set the Header Cell Factor to 1 otherwise they will look like decimals such as 1.2 or 1.6 instead of 1200 and 1600
Values: cut and paste these from the VE table in the VCM Editor by right clicking anywhere in that table and choosing Column Axis / Copy Labels
Row Axis
Parameter: and this is our Y axis aka Manifold Absolute Pressure [Sensor] so kPa
Values: cut and paste these from the VE table in the VCM Editor by right clicking anywhere in that table and choosing Row Axis / Copy Labels
Last edited by Gregski; 02-20-2020 at 11:20 AM.
|