View Single Post
Old 08-04-2018, 09:41 PM   #25
dmjlambert
Senior Member
 
dmjlambert's Avatar
 
Join Date: Apr 2016
Location: Cypress, TX
Posts: 3,567
Re: Parallel Flow Condenser

Quote:
Originally Posted by RichardJ View Post
NO.
The first thing you will notice about a parallel flow is the large round tanks on both ends. The second is that the horizontal tubes are flat instead of the old style round tubes. The side tanks are chambered so that the refrigerant flows horizontally in 3 or 4 lines, then drops down and flows back in the next group of lines.
Thanks for that picture and description, that helps. The picture of the condenser with A and B dimensions is interesting. Is it from a vendor who will sell me a condenser if I just specify the A and B dimensions? If so, perhaps brackets that I would need to fit the truck could be added or clamps fabricated.

Regarding the Jegs listing for the Vintage Air condenser, is -6AN and -8AN fittings what connects to the existing factory setup, or would I need to get some sort of adapters or tubes made? That looks like a good find, I will give them a call at Vintage Air and ask more about it.
dmjlambert is offline   Reply With Quote