Re: 71 350 running hot coolant backup up problem - Test #3
so here are the results of the third test drive, this one is for all of you who suggested swapping to a 180* thermostat
180 Thermostat, running 50/50 water coolant mix, still 12 degrees initial timing
as you can see we were averaging in the high 190s, here I caught it at 199* F degrees this only proves now we are masking the problem instead of fixing it, how do I know that?, well my '74 truck is running a 180* thermostat and it operates at you guessed it 180* degrees year round
|