Re: Ignition switch failures.

Motors can sometimes turn into generators. I worked on a car that would run for 4-5 seconds after the ignition was turned off. The fix was to install a diode between the trans cooler fan and an ignition voltage source. In this specific case, we were powering the fan from an aux fuse panel fed by the main fuse panel ignition bus.

I also had a similar problem with an alternator, where I had to use a diode in series with the exciter wire.