Re: Does Auxiliary fuse box need constant power?
Quote:
Originally Posted by silverminer
may i suggest the following relay block solution that i have been running nearly 3 years now without any trouble: bussman 37702-3fn3625. A 12v 70amp continous duty relay that works beautifully underhood. I've purchased them for two separate vehicles, zero issues.
Run an ignition-on source from the primary fuse block under the dash to trigger the relay, run a suitable gauge 12v constant supply from the back of the starter terminated with a fusible link to the relay block, and then supply your independent auxiliary fuse block. My only complaint with the bussman 37702 is that the trigger wiring is intended to use a metri-pack connector which i was unable to purchase on an individual basis - online sources required a bulk buy of a dozen or more. I solved the problem with metri-pack sleeves without the plastic part.
|
10-4
Attachment 2058247
Attachment 2058249
__________________
Insert clever text here:
Last edited by Greasey Harley; 10-31-2020 at 03:46 AM.
|