Old 11-19-2017, 09:46 PM   #1
andrewpclayton
Registered User
 
andrewpclayton's Avatar
 
Join Date: Aug 2017
Location: Eugene Oregon
Posts: 128
Heater stopped working, blowing fuses, melted the wire connector

Hi everyone
Recently I broke the arms on my heater (no ac) so I got the unbreakable levers from Brothers. I put them on a week or two ago and all was good.
Today I noticed my heater wasn’t on and the fuse was blown. I put a new fuse in and it blew right away.
I looked at the wires that plug into the switch and it was a little bit melted at the bottom most terminal

I will need new wiring harness for the heater, but do you think also I need a new switch? Or whole new heater control? Is there something else that may be or is likely the culprit?
Posted via Mobile Device
andrewpclayton is offline   Reply With Quote
Old 11-19-2017, 10:40 PM   #2
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 25,331
Re: Heater stopped working, blowing fuses, melted the wire connector

-
I would replace the switch too. I would also check the heater resistor located in the heater duct. (follow the wires to it) It may be shorted inside. I can't remember if the screws are 1/4" or 5/16", 5/16" I think. Careful when you remove it, the wire coils are pretty fragile.

A heater motor that is dragging or squirrel cage that is full of mouse nests might cause the electrical components to overheat too.

LockDoc
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-
LockDoc is offline   Reply With Quote
Old 11-19-2017, 10:51 PM   #3
andrewpclayton
Registered User
 
andrewpclayton's Avatar
 
Join Date: Aug 2017
Location: Eugene Oregon
Posts: 128
Quote:
Originally Posted by LockDoc View Post
-
I would replace the switch too. I would also check the heater resistor located in the heater duct. (follow the wires to it) It may be shorted inside. I can't remember if the screws are 1/4" or 5/16", 5/16" I think. Careful when you remove it, the wire coils are pretty fragile.

A heater motor that is dragging or squirrel cage that is full of mouse nests might cause the electrical components to overheat too.

LockDoc
Ok cool that all makes sense. I was recently in the heater core box on the outside so no rats in there lol
Posted via Mobile Device
andrewpclayton is offline   Reply With Quote
Old 11-20-2017, 01:57 AM   #4
andrewpclayton
Registered User
 
andrewpclayton's Avatar
 
Join Date: Aug 2017
Location: Eugene Oregon
Posts: 128
Re: Heater stopped working, blowing fuses, melted the wire connector

I had an extra wiring harness so I decided to hook it up. Blew a fuse again, a little smoke from the fuse box and the switch on the heater control was hot. I’m going to get a whole new assembly to see if that fixes it.. the reconditioning kit I used looks kinda ****ty anyway with the sticker decal .
__________________
1977 SWB (c20 conversion) SBC350
Springfield Oregon
Instagram: @nevernotchevy
andrewpclayton is offline   Reply With Quote
Old 11-20-2017, 11:02 AM   #5
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 25,331
Re: Heater stopped working, blowing fuses, melted the wire connector

Quote:
Originally Posted by andrewpclayton View Post
I had an extra wiring harness so I decided to hook it up. Blew a fuse again, a little smoke from the fuse box and the switch on the heater control was hot. I’m going to get a whole new assembly to see if that fixes it.. the reconditioning kit I used looks kinda ****ty anyway with the sticker decal .

Let us know if that cures the fuse problem.

LockDoc
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-
LockDoc is offline   Reply With Quote
Old 01-02-2018, 10:11 PM   #6
andrewpclayton
Registered User
 
andrewpclayton's Avatar
 
Join Date: Aug 2017
Location: Eugene Oregon
Posts: 128
Re: Heater stopped working, blowing fuses, melted the wire connector

Replaced the blower motor and connected it with a better ground wire than i had, and it works! thanks for the suggestions
__________________
1977 SWB (c20 conversion) SBC350
Springfield Oregon
Instagram: @nevernotchevy
andrewpclayton is offline   Reply With Quote
Old 01-02-2018, 11:35 PM   #7
toolboxchev
Registered User
 
Join Date: Jul 2015
Location: 2nd left past the stump on a dirt road.
Posts: 2,629
Re: Heater stopped working, blowing fuses, melted the wire connector

Quote:
Originally Posted by LockDoc View Post
-
I would replace the switch too. I would also check the heater resistor located in the heater duct. (follow the wires to it) It may be shorted inside. I can't remember if the screws are 1/4" or 5/16", 5/16" I think. Careful when you remove it, the wire coils are pretty fragile.

A heater motor that is dragging or squirrel cage that is full of mouse nests might cause the electrical components to overheat too.

LockDoc
X2 on that, also if the motor is older and electrically worn it will pull more amps to keep it working and do exactly like blowing fuses.
toolboxchev is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies