The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1973 - 1987 Chevrolet & GMC Squarebody Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 07-07-2009, 07:16 PM   #1
cjracing15
Registered User
 
cjracing15's Avatar
 
Join Date: Jan 2007
Location: Lexington, TN
Posts: 1,427
Re: Tbi swap build thread

Quote:
Originally Posted by pancake View Post
Hello again, I have a quick question.

If I use a adapter plate to bolt the TBI to a carb intake:

1) are there rules on whereto mount the sensors that were mounted to the TBI intake.

2) can I use a diffrent coil mounted to the firewall? what kind of coil do I need?

Thanks again.
1) I would put the sensors as close as I could as the factory did it.

2) As for the coil I am not sure. I am sure RF will chime in on it. He rocks on the wiring diagrams.
__________________
The fleet
94 Chevy 4x4 reg cab
2018 Traverse (wifes car)
1977 SWB stepside
1949 Chevy truck
cjracing15 is offline   Reply With Quote
Old 07-07-2009, 08:27 PM   #2
rfmaster
Registered User
 
rfmaster's Avatar
 
Join Date: Oct 2003
Location: OC CA
Posts: 1,374
Re: Tbi swap build thread

Quote:
Originally Posted by cjracing15 View Post
1) I would put the sensors as close as I could as the factory did it.

2) As for the coil I am not sure. I am sure RF will chime in on it. He rocks on the wiring diagrams.
Thanks CJ

Pancake - you can mount coil on the fire wall (or in its original location). If you do so make sure to run a ground strap (braid) between intake and coil mounting bracket. Low resistance ground return path is required between EST and coil.

I have seen third gen boys mount monster sized coils (lots money) on the firewall. Generally, performance coils can be saver and trouble all rolled into one. The problem stems from current requirement that these coils place on EST module (inside dizzy). To get HV coil to deliver joules of spark energy (at 40 - 50kV) requires more current flowing through the primary (12 volt winding). EST module operates as a switch which turns on & off current flowing through the coils primary windings. More current = more heat. Semiconductor devices do not like heat and fail over time if subjected to operation beyond rated limits. For our trucks, with engines spending most of their lives below 3000 RPMs use of 'monster' coils is not necessary.

One of these days I'll setup experiment in my lab to measure primary coil winding current and publish my results. I have factory coils, but I do not have any 'monsters' for obvious reasons.

As to recommendation on coil - I have never used anything but stock, hence I can not recommend one.

Sensor placement. I prefer to mount my sensors away from heat sources for the aforementioned reasons. I mounted my MAP on the firewall, ESC module is mounted on fender skirt. All my relays are mounted away from engine. GM mounted the same sensors on a bracket bolted to intake manifold.

//RF
__________________
"The Beast"

1975 Chevrolet C20 longbed
350/700R4! with 3inch body lift
Dual Flowmasters Super 40's!
TBI retrofit completed (2007-07-29)
New 383CID (+030) 08-304-8 9.5:1CR x36,005 (2012-12-17)
rfmaster is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 11:43 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com