Thread
:
4L80E & TH400 Tech.
View Single Post
04-27-2015, 07:08 PM
#
11
clinebarger
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
Re: 4L80E & TH400 Tech.
Blocking the 2-3 Accumulator. (TH400)
You will need a 5/16-18 tap & a 5/16" set screw.
Tap it just deep enough for the set screw to seat good.
The red arrow is the accumulator feed hole that needs to be tapped & plugged.
Attached Images
clinebarger
View Public Profile
Find More Posts by clinebarger