the second test and the more official one was the Horse Shoe Test
this is where we put our Multimeter on the horse shoe icon and check for The Reistance
the 1-2 solenoid measured at 23.1 ohms
the 2-3 solenoid measured at 23.3 ohms
both seemed within range, remember if you know nothing but have two of something, compare them
then here's how the new ones tested
the new 1-2 solenoid measured 25.6 ohms
the new 2-3 solenoid measured 27.7 ohms