Re: Heater/AC motor not blowing

Finally fixed it. Behind the glove box is a connector wrapped in foam that is a constant hot to the relay. It contains a ground that is used for both the blower and the actuator doors. At some point it melted partially and was no longer connecting either wire. Clipped out the connector and replaced with crimped butt connectors. Voila! Ran an extra ground off the blower wire ground just in case while I was in there.

Moral of the story: The factory service manuals are way more helpful than the Haynes manual when it comes to electrical troubleshooting.