The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > General Truck Forums > Engine & Drivetrain > LSx Swaps

Web 67-72chevytrucks.com


 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
Old 05-16-2014, 07:19 PM   #11
dayj1
Senior Member
 
Join Date: Jul 2009
Location: Athens, AL
Posts: 499
Re: Ford Windstar E-Fan Wiring Question

Quote:
Originally Posted by First c10 View Post
I have a question regards to diagram 2 and the last diagram. Aren't they the same but with only one 47 ohm resister and coil?
If I understand right, you're asking about the difference between the last and the second to last diagram. If so, the last one does not control the low speed fan relay at all. It allows you to "leave out" two diodes and a resistor and a couple of wires.

Quote:
Originally Posted by First c10 View Post
don't you have to have the low speed relay grounded by the PCM to get high speed ground to work?
No. The 3 relay setup has some redundancy built in. At least one fan will run at full speed if any of the relays fail or if only one of the control lines is working.