72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Ok, so here's the deal. I'm trying to get the factory ac working again.
Here's what I've been through over the past couple weeks and info regarding system. I've replaced the compressor with a remanufactured one, new a/c expansion valve, new R134 updated POA valve with clutch switch kit, 134 fittings, new control cables, all flaps working properly, new vacuum lines, & the condenser is flowing. Also, when I replaced the compressor today I looked to see if the bag had busted in the filters looking for little black pieces and found nothing which would make me think the condenser is fine. Just cant get it cold. vents say about 78-80degress maybe slightly colder while driving, but not under 70ish. Also, tried different lb amounts ranging from 2 lbs to 3 3/4lbs as recommended from factory (which makes the compressor knock slightly and sweat on the outside of the compressor itself)
Hope al this helps. Someone cure my woes!!

Thanks
dlct3 is offline   Reply With Quote
Old 06-21-2014, 01:12 AM   #2
newstang79
Registered User
 
Join Date: Oct 2008
Location: Indianola, Iowa
Posts: 11
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Make sure your heater hose valve to stop hot water to heater core is stopping flow to core. If it is allowing water to circulate (if they both are hot) you will never get cold air no matter what you do. If your large line (suction) is sweating back to compressor you have a full charge.
newstang79 is offline   Reply With Quote
Old 06-21-2014, 07:52 AM   #3
Bigdav160
Registered User
 
Bigdav160's Avatar
 
Join Date: Apr 2011
Location: Klein Texas
Posts: 3,852
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Out of curiosity, what type of oil did you use? You didn't replace the drier?

I'm not saying that is the problem. The OE condenser is going to be too small for R134a

What are the pressures? That's important.
__________________
My Classics:
'72 K20 Suburban + '65 Dodge Town Wagon
'72 Corvette Roadster +'67 Corvette Roadster
'73 Z-28 Camaro
'63 Ford SWB Uni Pickup
'50 Ford Coupe
Bigdav160 is offline   Reply With Quote
Old 06-21-2014, 08:10 AM   #4
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

[QUOTE=Bigdav160;6729854]Out of curiosity, what type of oil did you use? You didn't replace the drier?

I'm not saying that is the problem. The OE condenser is going to be too small for R134a

What are the pressures? That's

I'm not sure on these answers exactly as I had a mechanic completing most of these. I know he used an ac oil that was died green when he filled the compressor. I'll pass the info on to him about the co sensor and try to get answer on what the pressures were. Seems like hee ruined low side was around 40 but don't quote me for sure
dlct3 is offline   Reply With Quote
Old 06-21-2014, 08:13 AM   #5
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Quote:
Originally Posted by newstang79 View Post
Make sure your heater hose valve to stop hot water to heater core is stopping flow to core. If it is allowing water to circulate (if they both are hot) you will never get cold air no matter what you do. If your large line (suction) is sweating back to compressor you have a full charge.
Ok. Can you lead me in the right direction as to where this is located and best way to check and test it? I do believe it was sweating. I'll verify. Thanks for the help guys. Really appreciate it. The next step he was going to take was replacing the compressor with a 10 valve
dlct3 is offline   Reply With Quote
Old 06-21-2014, 08:44 AM   #6
GSFMECH
On the road

 
GSFMECH's Avatar
 
Join Date: Jan 2004
Location: NATCHITOCHES LOUISIANA
Posts: 809
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

You mentioned you used the POA valve w/ switch? If this is the one from Old Air products it has an adjustable pressure switch, you are going to have to adjust it so the low side pulls down to about 25- 26 psi or so. Pull the plug off and look in the end and you'll see a screw, this is the adjuster. Go only a little at a time. I never had luck with those, I personally like keeping the original POA valve and adjusting it down so it maintains 26 psi or so in the evaporator. It will take about 56 oz or so of 134A to fill it properly. I've been fighting these factory units for the last 25-30 years.
__________________
Mike

Castro- 72 SWB. Ochre and White. 496/400 turbo, GV OD ,Dakota Digital dash , tilt, Vintage Air, PS, hydro boost, factory buckets, console, QA-1 Coil over suspension, 20/20"Billet Specialties Magnetos

72 SWB. Med blue. 454/400 turbo, tach, tilt, Stock AC, PS,PDB, factory buckets, console, ECE 4/6 drop w/ 2" blocks and C-notch, 20/20"Coys- Crashed and destroyed by drunk driver Sept 2019. New 72 build in the works.

My new build thread "Castro"
https://67-72chevytrucks.com/vboard/...d.php?t=820934

My old build thread, the blue truck
http://67-72chevytrucks.com/vboard/s...d.php?t=271489

www.louisianaclassictruckclub.com
GSFMECH is offline   Reply With Quote
Old 06-21-2014, 08:48 AM   #7
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Ok. More great tips. I'll pass these along. Here is what I have from classic parts
(1967-72) POA Valve Update Kit - R134
Item Number: 68-969B

Is this one adjustable as well you think?
dlct3 is offline   Reply With Quote
Old 06-21-2014, 08:54 AM   #8
Bigdav160
Registered User
 
Bigdav160's Avatar
 
Join Date: Apr 2011
Location: Klein Texas
Posts: 3,852
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

The switch is adjustable. There should be a screw head between the electrical blades.
__________________
My Classics:
'72 K20 Suburban + '65 Dodge Town Wagon
'72 Corvette Roadster +'67 Corvette Roadster
'73 Z-28 Camaro
'63 Ford SWB Uni Pickup
'50 Ford Coupe
Bigdav160 is offline   Reply With Quote
Old 06-21-2014, 08:55 AM   #9
GSFMECH
On the road

 
GSFMECH's Avatar
 
Join Date: Jan 2004
Location: NATCHITOCHES LOUISIANA
Posts: 809
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Most likely, if you pull the electric plug off, look between the prongs and there should be a screw, if you go too far with it it'll mess the switch up so take it easy. The valve newstang was talking about is in the heater hose and should be mounted to the inner fender, if you have leaking flaps it will affect it. Big thing is to get the charge right and get the pressure setting on the switch right and it should work, the problem I had was with the setup you have was it cycled too quickly, at first it would work good for a while and then freeze up. I think it may be because of this system having an expansion valve instead of a fixed orifice. I gave up and went with the original POA valve but you need to test them and readjust them for 134A.
__________________
Mike

Castro- 72 SWB. Ochre and White. 496/400 turbo, GV OD ,Dakota Digital dash , tilt, Vintage Air, PS, hydro boost, factory buckets, console, QA-1 Coil over suspension, 20/20"Billet Specialties Magnetos

72 SWB. Med blue. 454/400 turbo, tach, tilt, Stock AC, PS,PDB, factory buckets, console, ECE 4/6 drop w/ 2" blocks and C-notch, 20/20"Coys- Crashed and destroyed by drunk driver Sept 2019. New 72 build in the works.

My new build thread "Castro"
https://67-72chevytrucks.com/vboard/...d.php?t=820934

My old build thread, the blue truck
http://67-72chevytrucks.com/vboard/s...d.php?t=271489

www.louisianaclassictruckclub.com
GSFMECH is offline   Reply With Quote
Old 06-25-2014, 01:13 PM   #10
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Ok, So heres a quick update. Any advice now?

The POA valve set screw should be working fine and adjuted correctly according to mechanic. He said it was going down to 25-26 on the low side. Also, I took a couple pair of flat vise grips and pinched the heater core lines off to check the heater valve and the air conditioner on high went from 85 degrees driving down the road to about 70 degrees driving at the center vent. so a decent swing, but still not cold. Mechanics going to drain the refigerant and refil as he said he had it colder when he had less lbs of r134. about 2.5 to 3 cans instead of the almost 5 cans factory recomends (12oz cans) The POA valve itself is cool and dripping, but not cold like it should be.

Anyone care to advise? Thanks again
dlct3 is offline   Reply With Quote
Old 06-25-2014, 02:59 PM   #11
JointTech
Registered User
 
JointTech's Avatar
 
Join Date: Feb 2012
Location: Mission Viejo, CA
Posts: 1,856
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

what temp should a factory AC be blowing? I read a post yesterday and it seemed like the guy was really stoked it was blowing at 65. From what I remember it should be way colder than that at the vent for modern cars.
__________________
72 C20 Long Bed
SB350 TH400 14 bolt rear end
Extremely boring build thread
JointTech is offline   Reply With Quote
Old 06-25-2014, 03:09 PM   #12
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

I've read and been told around 38-44 at the vent which is what others are seeing on same systems
dlct3 is offline   Reply With Quote
Old 06-25-2014, 03:11 PM   #13
JointTech
Registered User
 
JointTech's Avatar
 
Join Date: Feb 2012
Location: Mission Viejo, CA
Posts: 1,856
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

ok thats what I thought. Now to find that other thread and let that guy know his AC isnt cold maybe hes somewhere cold so it doesnt matter.
__________________
72 C20 Long Bed
SB350 TH400 14 bolt rear end
Extremely boring build thread
JointTech is offline   Reply With Quote
Old 06-25-2014, 03:44 PM   #14
leddzepp
Moderator
 
leddzepp's Avatar
 
Join Date: May 2007
Location: Southern Cal
Posts: 19,990
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Your factory AC system will never get as cold as it should with R-134, unless you get a modern condensor designed for it. I played games with that crap on several trucks. I went back to R-12 and will never use R-134 again on a factory system. My truck stays ice cold sitting in dead stop traffic in 110 degree heat with no problems now.
__________________
1972 C/10 Cheyenne Super SWB. Restored, loaded, slammed.

1968 C/10 50th Anniversary LWB. Unrestored, stock, daily driver/work truck.


RIP ElJay
RIP 67ChevyRedneck
RIP Grumpy Old Man
leddzepp is offline   Reply With Quote
Old 06-25-2014, 04:00 PM   #15
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Quote:
Originally Posted by leddzepp View Post
Your factory AC system will never get as cold as it should with R-134, unless you get a modern condensor designed for it. I played games with that crap on several trucks. I went back to R-12 and will never use R-134 again on a factory system. My truck stays ice cold sitting in dead stop traffic in 110 degree heat with no problems now.
I think that may be my next step but I know of other systems on r-134 that are low 40's so what I have should certainly be a whole lot better. unfortunately, now i have a poa valve for r134 and if r12 doesnt make a difference I've wasted that $$ as well which probably isnt very cheap is it?
dlct3 is offline   Reply With Quote
Old 06-25-2014, 05:01 PM   #16
1972SUPERSB
Registered User
 
1972SUPERSB's Avatar
 
Join Date: Sep 2012
Location: San Antonio, TX
Posts: 1,026
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

I just rebuilt my factory AC and replaced just about everything in it. Only thing I kept was the evaporator and I just flushed it out. It blows 45 degrees out of the vents. If you do it right R134 is just fine
__________________
Jeff

1972 Cheyenne Super SWB 350, Auto, Bucket Seats w/Console, Tach, Factory A/C, P/S ,P/B, Tilt

1998 Chevy 1500 Ext Cab 5.7, Pewter w/blue interior
1972SUPERSB is offline   Reply With Quote
Old 06-25-2014, 05:11 PM   #17
dlct3
Registered User
 
Join Date: May 2014
Location: Laurie MO
Posts: 41
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Quote:
Originally Posted by 1972SUPERSB View Post
I just rebuilt my factory AC and replaced just about everything in it. Only thing I kept was the evaporator and I just flushed it out. It blows 45 degrees out of the vents. If you do it right R134 is just fine
Thansk for sharing. can you tell me what you replaced besides the compressor, poa valve, and evaporator? Also, what dryer did you use?
dlct3 is offline   Reply With Quote
Old 06-25-2014, 05:37 PM   #18
joey8383
Registered User
 
joey8383's Avatar
 
Join Date: May 2012
Location: Okmulgee, OK
Posts: 205
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

The compressor sweating tells me the suction line is pretty cold and well below the dew point (and the evaporator is cold too). Really need to get the pressure readings, outdoor temp, and a cab temp. Roughly, your condensing temp (high side converted to temp) should be ABOUT 30 degrees higher than the outdoor temp. If it still has the small R12 condenser on it, you may see higher head pressure. The only way to get the charge right is to vacuum it and weigh it in. I suspect the heater valve is open and your heater core is flowing hot water through it. Are both heater core lines hot? Grab some crimp pliers and pinch off the heater hose and see what happens. But really need more info/readings. Good luck!
joey8383 is offline   Reply With Quote
Old 06-25-2014, 05:47 PM   #19
1972SUPERSB
Registered User
 
1972SUPERSB's Avatar
 
Join Date: Sep 2012
Location: San Antonio, TX
Posts: 1,026
Re: 72 c10 Factory Air Conditioning Advice Needed?? Not blowing COLD!

Quote:
Originally Posted by dlct3 View Post
Thansk for sharing. can you tell me what you replaced besides the compressor, poa valve, and evaporator? Also, what dryer did you use?
I replaced the compressor with the one from old air products, all new hoses, new AC delco drier, poa valve, new condenser, AC delco expansion valve,
__________________
Jeff

1972 Cheyenne Super SWB 350, Auto, Bucket Seats w/Console, Tach, Factory A/C, P/S ,P/B, Tilt

1998 Chevy 1500 Ext Cab 5.7, Pewter w/blue interior
1972SUPERSB is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 04:44 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com