Old 01-30-2022, 02:01 AM   #1
Coach
Registered User
 
Coach's Avatar
 
Join Date: Oct 2014
Location: brentwood, ca.
Posts: 109
Ignition Module recommendation

Can anyone recommend a quality ignition module for my GM HEI Distributor - I've gone through (2) Standard Motor Products LX301's in the last couple months.
__________________
1967 Chevy C10 Stepside SWB - 350/700r4
Coach is offline   Reply With Quote
Old 01-30-2022, 11:25 AM   #2
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 25,370
Re: Ignition Module recommendation

Quote:
Originally Posted by Coach View Post
Can anyone recommend a quality ignition module for my GM HEI Distributor - I've gone through (2) Standard Motor Products LX301's in the last couple months.

Might try your local GM dealer. Probably pay a little premium.

I started using computer thermal heat sink paste (Arctic Silver) on the modules instead of the stuff that comes with the new ones.

https://www.amazon.com/Arctic-Silver.../dp/B07NV27PDX

I think it works better. All you need is a real thin skim coat. You may be able to find it cheaper if you look around.

LockDoc
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-
LockDoc is offline   Reply With Quote
Old 01-30-2022, 12:30 PM   #3
BigBird05
Senior Member
 
Join Date: Aug 2019
Location: Cheraw
Posts: 1,305
Re: Ignition Module recommendation

When it comes to electronics always try to buy OEM parts. If you are going thru modules check your voltage at the distributor when the truck is running. These modules don't like low voltage.
BigBird05 is offline   Reply With Quote
Old 01-30-2022, 12:32 PM   #4
truckster
Senior Member
 
truckster's Avatar
 
Join Date: Jan 2001
Location: Orem, Utah
Posts: 7,832
Re: Ignition Module recommendation

I agree with the silver thermal paste - it's way better.

Also check your voltage at the distributor.
__________________
I have sworn upon the altar of God, eternal hostility against every form of tyranny over the mind of man. - Thomas Jefferson
truckster is offline   Reply With Quote
Old 01-30-2022, 12:53 PM   #5
tdangle
Senior Member
 
tdangle's Avatar
 
Join Date: Mar 2005
Location: Jurupa Valley, Ca
Posts: 1,210
Re: Ignition Module recommendation

Something is taking them out. I ran a cheap HEI clone for years with no problem. Make sure you have full battery voltage at the distributor. running should be between 13.5 and 14.5 volts. Also when replacing the module, use the paste as this helps transfer heat from the module to the body of the distributor.
__________________
Terry

1970 Custom Camper/C20 , GM Crate 350/7004R, Dana 60, factory AC
tdangle is offline   Reply With Quote
Old 01-30-2022, 05:51 PM   #6
Coach
Registered User
 
Coach's Avatar
 
Join Date: Oct 2014
Location: brentwood, ca.
Posts: 109
Re: Ignition Module recommendation

Thanks fellas. I have 13.8 volts when running. I am going to try the silver paste and an AC Delco D1906 module and see how that goes.
__________________
1967 Chevy C10 Stepside SWB - 350/700r4
Coach is offline   Reply With Quote
Old 01-30-2022, 08:40 PM   #7
toolboxchev
Registered User
 
Join Date: Jul 2015
Location: 2nd left past the stump on a dirt road.
Posts: 2,629
Re: Ignition Module recommendation

Quote:
Originally Posted by Coach View Post
Can anyone recommend a quality ignition module for my GM HEI Distributor - I've gone through (2) Standard Motor Products LX301's in the last couple months.
Lets first start at the root of a common problem.

Do you have an upgraded internally regulated alternator or do you still have the stock external voltage regulator?

Excessive voltage demands with the external system lead to high voltage spikes which in turn fry the HEI modules. I go through one about every 1 to 2 years. The internally regulated alternators do not let the amp/voltage spike when demand is high. I believe from knowledge passed about on the board the internally regulated unit do not let charging increase past somewhere around 14.0 volts.

It follows classic electrical theory in battery charging lower voltages and longer charge times do not cook the standard lead acid battery.
toolboxchev is offline   Reply With Quote
Old 01-30-2022, 10:46 PM   #8
68 P.O.S.
Registered User
 
Join Date: Jan 2007
Location: Puyallup, WA
Posts: 1,660
Re: Ignition Module recommendation

Check on your coil. HEI coils can overheat and layer short, which can take out modules pretty quickly.
__________________
72 C10 lwb fleetside -stock 350/350 combo
68 P.O.S. is offline   Reply With Quote
Old 01-31-2022, 08:43 AM   #9
Bigdav160
Registered User
 
Bigdav160's Avatar
 
Join Date: Apr 2011
Location: Klein Texas
Posts: 3,852
Re: Ignition Module recommendation

Quote:
Originally Posted by 68 P.O.S. View Post
Check on your coil. HEI coils can overheat and layer short, which can take out modules pretty quickly.
That's what I was going to say. The coil is the likely root cause here.
__________________
My Classics:
'72 K20 Suburban + '65 Dodge Town Wagon
'72 Corvette Roadster +'67 Corvette Roadster
'73 Z-28 Camaro
'63 Ford SWB Uni Pickup
'50 Ford Coupe
Bigdav160 is offline   Reply With Quote
Old 01-31-2022, 09:52 AM   #10
toolboxchev
Registered User
 
Join Date: Jul 2015
Location: 2nd left past the stump on a dirt road.
Posts: 2,629
Re: Ignition Module recommendation

Quote:
Originally Posted by 68 P.O.S. View Post
Check on your coil. HEI coils can overheat and layer short, which can take out modules pretty quickly.
Would venture to speculate that an over voltage situation would do this also. I have seen my own vehicle pump out over 19 volts at idle when the external voltage regulator goes bad.
toolboxchev is offline   Reply With Quote
Old 01-31-2022, 02:00 PM   #11
Coach
Registered User
 
Coach's Avatar
 
Join Date: Oct 2014
Location: brentwood, ca.
Posts: 109
Re: Ignition Module recommendation

The frustrating part is the module (LX301) and coil (DR31) were both replaced at the same time a couple months ago, just to be safe. I will probably replace both this time as well, as i am going to be putting the truck up for sale to help pay for my son's college and I don't want to sell the truck to someone with any issues.
__________________
1967 Chevy C10 Stepside SWB - 350/700r4
Coach is offline   Reply With Quote
Old 02-03-2022, 11:39 AM   #12
68 P.O.S.
Registered User
 
Join Date: Jan 2007
Location: Puyallup, WA
Posts: 1,660
Re: Ignition Module recommendation

Quote:
Originally Posted by toolboxchev View Post
Would venture to speculate that an over voltage situation would do this also. I have seen my own vehicle pump out over 19 volts at idle when the external voltage regulator goes bad.
Yes, most definitely
__________________
72 C10 lwb fleetside -stock 350/350 combo
68 P.O.S. is offline   Reply With Quote
Old 02-03-2022, 11:42 AM   #13
68 P.O.S.
Registered User
 
Join Date: Jan 2007
Location: Puyallup, WA
Posts: 1,660
Re: Ignition Module recommendation

Another idea, check to see if you still have the stock resister power wire in place. It was meant for the points distributor and will not give the proper voltage. If so, it needs to be changed.
__________________
72 C10 lwb fleetside -stock 350/350 combo
68 P.O.S. is offline   Reply With Quote
Old 02-03-2022, 07:17 PM   #14
TALLone71
Registered User
 
Join Date: Nov 2017
Location: Richmond va
Posts: 179
Re: Ignition Module recommendation

thanks locdoc, for the tip on the thermal paste, I have always used the grease they supply with the new module, but have wondered about a better thermal barrier, and this looks like the ticket!
TALLone71 is offline   Reply With Quote
Old 02-03-2022, 08:45 PM   #15
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 25,370
Re: Ignition Module recommendation

Quote:
Originally Posted by TALLone71 View Post
thanks locdoc, for the tip on the thermal paste, I have always used the grease they supply with the new module, but have wondered about a better thermal barrier, and this looks like the ticket!

No problem. Just remember a thin skim coat. Too much can be as bad as not enough....

LockDoc
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-
LockDoc is offline   Reply With Quote
Old 02-03-2022, 09:27 PM   #16
leftybass209
Registered User
 
leftybass209's Avatar
 
Join Date: Feb 2011
Location: Modesto, CA
Posts: 2,186
Re: Ignition Module recommendation

To keep replacing modules is probably not coincidence at this point. Bad grounding can kill a module. Do you know if the bent metal ground strap is inside the cap under the coil?

Ground straps to motor okay?

It's possible you have higher resistance for the ground when driven at temp. Did you verify voltage on a hot motor, hot day?

I just think... if you're a capable mechanic, and you used thermal paste, then 1 new burn out is a fluke, 2 is suspect that it's not the module. The difference in thermal paste isn't so great that the stuff provided shouldn't give you years of use. Best of luck getting it sorted.
leftybass209 is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 04:16 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com